Download Modeling and Analysis of CH HVAC by Rishel PDF

By Rishel

Show description

Read Online or Download Modeling and Analysis of CH HVAC PDF

Similar technique books

Woodworking Shopnotes 025 - Special Table Saw Issue

Each web page of ShopNotes journal will make you a greater woodworker, since you get extra woodworking plans, extra woodworking suggestions, extra woodworking jigs, and extra approximately woodworking instruments — and never a unmarried advert. For greater than 25 years, woodworkers have grew to become to ShopNotes for the main precise woodworking plans and woodworking assistance on hand at any place.

Encyclopedia of Environmental Science and Engineering

Thoroughly revised and up-to-date, Encyclopedia of Environmental technology and Engineering, 5th variation spans the full spectrum of environmental technological know-how and engineering. nonetheless the main finished, authoritative reference to be had during this box, the enormous two-volume encyclopedia has increased to incorporate 87 articles on subject matters starting from acid rain, pollution, and group future health, to environmental legislation, instrumentation, modeling, substitute strength, toxicology, radioactive waste, and water therapy.

Memorial tributes. Volume 2

Honoring the deceased contributors and overseas affiliates of the nationwide Academy of Engineering, this quantity is a permanent list of the numerous contributions of engineering to humankind. This moment quantity of Memorial Tributes covers the interval from January 1979 to April 1984.

Additional info for Modeling and Analysis of CH HVAC

Example text

One is the current high efficiency chiller shown in Table 7. For the purpose of this discussion this chiller is labeled chiller A. The other two include a high efficiency chiller and a lower efficiency chiller, both available and popular in 1995. These chillers are labeled as chillers B and C respectively. Data from these older chillers is presented below. 91 Table 9. Liu's High Efficiency Chiller (B) Tevap,out Tcond,in Load 1000 900 800 700 600 500 400 300 200 1000 900 800 700 600 500 400 300 1000 900 800 700 600 500 400 300 85 85 85 85 85 85 85 85 85 75 75 75 75 75 75 75 75 65 65 65 65 65 65 65 65 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 GPMcond GPMevap KW 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 3000 2400 Tevap Tcond 612 555 503 453 406 362 318 273 220 536 483 436 395 356 319 281 243 478 437 396 361 328 296 260 223 Table 10.

Comparisons were made data at 71%, 45% and 25% load conditions. Similar chiller efficiencies were attained by either varying flow rate or inlet temperature. In fact the variable and constant flow results agreed to within 1% of one another. Redden’s work concluded that varying evaporator water flow rate has little effect on chiller performance. C om pressor pow er [kW ] 600 500 1000 ton load 660 ton load 330 ton load o 44 setpoint o 75 condenerw aterinlet 400 300 200 100 1000 1500 2000 2500 3000 3500 E vap o rato r w ater flo w rate [g p m ] Figure 32.

It is expected that there is augmentation on the tubes inner surfaces which increases heat transfer between the chilled water and tube wall. This augmentation affects evaporator pressure drop. In order to model the evaporator pressure drop, an effective length and roughness were determined. In actuality, the evaporator is much shorter and rougher than this effective length and roughness indicate. Also, much of the evaporator pressure drop results from tube bends and header losses. 53 However, since the actual geometry is not available, effective values were used.